PELCO Technical Tips
| Miscellaneous |
| 5973005.PDF (34 KB) |
Preventing Water Damage |
| 5973021.PDF (37 KB) |
Choosing the Correct Coaxial Cable for CCTV Applications |
| 5973024.PDF (10 KB) |
24 VAC Wiring Distances Chart |
| 5983027.PDF (28 KB) |
Configuring a Windows 3.1 Computer for B.O.S.S.® Software |
| 5013043.PDF (82 KB) |
How to Obtain and Use Pelco Protocols |
| Camera Systems |
| 5033066.PDF (98 KB) |
How to Install a Heavy-Duty Spectra III Bubble in a Heavy-Duty Spectra II Lower Dome |
| 5023063.PDF (467 KB) |
How to Convert an Esprit System to 24 VDC Operation |
| 5003039.PDF (151 KB) |
Camclosure® Series Integrated Camera Systems - How to Disable the Line Lock Feature |
| 5993033.PDF (35 KB) |
How to Order Spectra LiteTM with Alarm Capabilities |
| 5983029.PDF (34 KB) |
CM6700 and Intercept® Compatibility |
| 5983028.PDF (33 KB) |
Moisture Gets Inside Outdoor Spectra® Dome |
| 5973017.PDF (35 KB) |
Spectra® Power Input (Revised 01/12/98) |
| 5973014.PDF (33 KB) |
Field-of-View Calculation for Spectra® Dome |
| 5973013.PDF (32 KB) |
LWM41 Retro Kit |
| Lenses |
| 5973023.PDF (157 KB) |
6-Pin Hirshmann |
| 5973022.PDF (72 KB) |
A Basic Guide to Generic Lens Connections |
| 5973012.PDF (34 KB) |
Changing Lens Speed |
| Enclosures |
| 5973002.PDF (41 KB) |
Connecting Camera Power on EH4700 and EH5700 Series Enclosures |
| Domes |
| 5973020.PDF (35 KB) |
Cleaning Acrylic Domes |
| 5973011.PDF (33 KB) |
Special Commands for Intercept® Domes Using AD2083 Translator |
| Scanners, Pan & Tilts |
| 5973016.PDF (34 KB) |
Pan Fixed Limit Stop |
| 5973010.PDF (38 KB) |
24 VAC Pan/Tilts Stop Scanning |
| Receivers |
| 5983031.PDF (39 KB) |
Pelco Receiver/Driver Types |
| 5973026.PDF (39 KB) |
Receiver/Driver and Matrix Compatibility |
| 5973015.PDF (34 KB) |
Wiring Pan Preset to ERD97P21-U |
| 5973008.PDF (33 KB) |
How To Clear All Presets From CX9000 Series Receiver/Driver |
| Digital Network Systems |
| 5013047.PDF (309 KB) |
Connecting PelcoNetTM Transmission System Units to a CM6800 And KBD200 for Remote ASCII Control |
| 5013046.PDF (263 KB) |
Connecting PelcoNetTM Transmission System Transmitter to the CM6800 ASCII Port |
| 5003042.PDF (115 KB) |
Connecting PelcoNetTM Transmission System Units... For Remote ASCII Control |
| 5003041.PDF (88 KB) |
Connecting a PelcoNetTM Transmission System Transmitter to the CM9502 ASCII Serial Port |
| 5003040.PDF (100 KB) |
Connecting a PelcoNetTM Transmission System Transmitter to the CM6700 ASCII Port |
| 5003037.PDF (232 KB) |
Connecting PelcoNetTM Transmission System Units For Remote Browser Control |
| 5003036.PDF (436 KB) |
Connecting PelcoNetTM Transmission System Units For Remote Communication |
| 5003035.PDF (265 KB) |
Connecting PelcoNetTM Transmission System Units to Various Components with Assorted Keyboards |
| Fiber Optics |
| 5053074.PDF (140 KB) |
Connecting PelcoFiberTM Transmission Systems to KBD300A Keyboard and to CM6800/CM6800E Matrix Switcher |
| Controls |
| 5973007.PDF (33 KB) |
"Low Power" Appears on MPT9500 Display |
| Matrix Switchers |
| 5053074.PDF (140 KB) |
Connecting PelcoFiberTM Transmission Systems to KBD300A Keyboard and to CM6800/CM6800E Matrix Switcher |
| 5053073.PDF (118 KB) |
Using the Updated VMX300(-E) Quad Video Display Gadget |
| 5043072.PDF (61 KB) |
How to Program the CM9760-MGR to Control Genex® Multiplexers |
| 5043071.PDF (68 KB) |
How to Recalibrate the CM9760-KBD Joystick for Optimized PTZ Control |
| 5033069.PDF (443 KB) |
Remotely Resetting the CM6700 Software from a Keyboard |
| 5033068.PDF (151 KB) |
How to Connect a CM9760-CDU-T to the CM6800E-48X8 |
| 5033065.PDF (81 KB) |
How to Select Polish or Russian Keyboard Layout for CM6800-MGR |
| 5013057.PDF (165 KB) |
How to Connect a CM9760-MDA to the CM6800-48X8 |
| 5013056.PDF (275 KB) |
How to Connect a CM9760-CDU-T to the CM6800-48X8 |
| 5013055.PDF (156 KB) |
How to Connect a CM9760-MDA to the CM6800-32X6 |
| 5013054.PDF (268 KB) |
How to Connect a CM9760-CDU-T to the CM6800-32X6 |
| 5013052.PDF (248 KB) |
Using a CM9760-DMR to Combine Multiple Control Devices |
| 5013051.PDF (189 KB) |
How to Configure a CM9760-DMR for Use as a Camera Control Expander |
| 5013050.PDF (215 KB) |
How to Configure a CM9760-DMR for Use as a Keyboard Expander |
| 5013049.PDF (91 KB) |
How to Connect a PC to the CM6800 Matrix Switcher |
| 5983030.PDF (34 KB) |
Resetting CM8500 When Alarms Lock Up |
| 5983029.PDF (34 KB) |
CM6700 and Intercept® Compatibility |
| 5973019.PDF (34 KB) |
CM6700 Keyboard Initialization |
| 5973018.PDF (35 KB) |
Programming Alarms For CM9502 |
| 5973009.PDF (33 KB) |
How To Remove Camera ID From CM7500 Matrix System Monitors |
| 5973006.PDF (35 KB) |
CM9500 Series Coaxitron® Matrix Switcher |
| 5973004.PDF (36 KB) |
"Jumpy" Text On CM8500 Monitor Output |
| 5973003.PDF (34 KB) |
How To Remove Camera ID, Date, Time From CM8500 |
| 5973001.PDF (36 KB) |
CM8500 Matrix - Miscellaneous Tips |
| Monitors |
| 5013045.PDF (188 KB) |
VIDEO4X4 Video Security System Installations Methods |
| Multiplexers/Quads |
| 5003038.PDF (49 KB) |
Compatibility of Other Manufacturer's Multiplexer Tapes with Pelco Genex® Multiplexers |
| 5983032.PDF (59 KB) |
MX4000 Multiplexer Programming from the KBD4000 Keyboard |
| Video Recorders |
| 5023062.PDF (47 KB) |
Updating the DX7000 Digital Video Recorder |
| 5013053.PDF (54 KB) |
DX7000RX Video Card Compatibility |
| 5013044.PDF (56 KB) |
Correcting Video Loss on DX1000 DVR |
| 5013048.PDF (180 KB) |
How to Install a DX3000 Series DVR with an MX4000 Series Genex® Multiplexer with PTZ Control |
| Miscellaneous Control Site |
| 5973025.PDF (438 KB) |
Troubleshooting ICI1000S and ICI2000D |
| Some Pelco products may not be available in all markets. Model numbers and specifications subject to change without notice. |
American Dynamics Technical Tips
| SpeedDomes & Accessories |
| Indoor Ultra Series Bubble Assembly |
TB_050702 |
| Loss of Dome Control in Hot Environments |
TB_021902 |
| Optima Dome |
TB_061901 |
| Optima Domes Cable Requirements |
TB_051402 |
| Reverse Pan After Upgrading Ultra I Firmware |
TB_050803 |
| RHIU2X2M Dome Mounts Grounding Clips |
TB_021102 |
| Tech Tips -DeltaDomes |
013001-01 |
| Controllers |
| Clearing Patterns with Keyboards or Touch Trackers |
TB_040902 |
| Digital Multiplexers |
| DigiClient Loses Connection with DigiMux |
TB_20031013_01 |
| DigiMux: Call Monitor Composite Video |
TB_20031013_06 |
| DigiMux: Compatible Devices |
TB_20040413_01 |
| DigiMux: DigiClient Video Aspect Ratio |
TB_20031103_01 |
| DigiMux: DigiMux Port Numbers |
TB_20031031_01 |
| DigiMux: E-Mail Notice Send Information |
TB_20031013_10 |
| DigiMux: Exiting DigiClient |
TB_20040302 |
| DigiMux: Exporting Information from a DigiMux |
TB_20021013_08 |
| DigiMux: How to Acess DigiMux from Behind a Router or Firewall |
TB_20040406_01 |
| DigiMux: How to Install a Dome with DigiMux |
TB_20031013_02 |
| DigiMux: Record Menu Limitations |
TB_20031013_07 |
| DigiMux: Unit Address Entry for DigiClient Installation |
TB_20031013_09 |
| How to Access an ADSensormatic Ultra Dome Menu via DigiMux |
TB_20031013_03 |
| Startup Indicator Lights on DigiMux |
TB_20031013_04 |
| Intellex Digital Video Management Solutions |
| Audio and the Bayfield Motherboard on Intellex 3.1 Platforms |
TB_20030826 |
| Configuring Extended Storages Modules (ESM) for NTFS format with Intellex 3.x Units |
TB_20040316 |
| Deleting Modems from Intellex 2.X |
TB_062801 |
| DSL & Cable Modem with Intellex |
TB_092101 |
| Incompatible CD-RW Drives |
TB-00013-00-141229 |
| Installing 7200-RPM Data Drives in Intellex Units |
TB_060703 |
| Integra Digital Video Recorder |
TB_021301-01 |
| Intellex / Network Client v2.0 |
TB_062201 |
| Intellex 1.x DAT Tape Drive Upgrade |
TB_110701 |
| Intellex 2.2 BMP File |
TB_062402 |
| Intellex 2.2 DV8000 Series Lock Ups |
TB_071002 |
| Intellex 2.4 Svideo to Composite "Pigtail" |
SB_071602 |
| Intellex 3.0, Start Up After Power Loss |
TB_012203 |
| Intellex 3.0, Start-Up |
TB_012703 |
| Intellex Alarm List Empty/Too Many Alarms |
TB_032802 |
| Intellex and Network Client Software 2.2 Build 17 |
TB_020802R1 |
| Intellex Build 17 Drive Configuration Instructions |
TBA020802 |
| Intellex Build 17 DriveConfig Instructions |
TBA020802 |
| Intellex DAT Drives Reliability |
TB_070201 |
| Intellex External Storage Limitations |
TB_110801 |
| Intellex Field Replaceable Parts List |
TB_021302 |
| Intellex Lessons Learned Appendix |
TBA013002 |
| Intellex Security Bulletin: Regarding Intellex and the Blaster Worm (Virus) |
TB_20030825 |
| Intellex Software Update (Version 2.2.18) |
TB_082002 |
| Intellex Software Update (Version 2.3) |
TB_091902 |
| Intellex Ultra BIOS Update |
TB 00071-00-061107 |
| Intellex v2.2 Monitor Pack Not Enabled |
TB_120301 |
| Intellex v2.2, 105 Error |
TB_032002 |
| Intellex v2.4 System Data Drives |
TB_112102 |
| Intellex v2.4.26 Maintenance Upgrade for the DV8000 |
TB_121102 |
| Intellex v2.4: Missing COM Port in Text Setup Screen |
TB_102202 |
| Intellex v2.x Hard Disk Full Warning |
TB_040202 |
| Intellex v2.X, Accessing CD-RW |
TB_102902 |
| Intellex v3.0 and External CD-RW Drive Limitation |
TB_010703R1 |
| Intellex v3.0 Call Monitor Update and BMP Images Patch |
TB_022603 |
| Intellex v3.0 Mis-Configuring Video Standards |
TB_030403 |
| Intellex v3.0 SP-1 Software Update |
TB_121802 |
| Intellex v3.0 Symptoms Associated with Bad Memory |
TB_ 031303 |
| Intellex v3.0 System Recovery Kits |
TB_060903 |
| Intellex v3.0 Tile Freeze |
TB_042903 |
| Intellex v3.0 Troubleshooting Tips |
TB_ 031403r1 |
| Intellex, ATI Video Card |
120100-01 |
| Intellex, CD-RW 105-Error Message |
TB_060602r1 |
| Intellex, External Modems |
TB_062002 |
| Intellex: Switching from Playback to Live causes Frozen or Black Video Images in v2.5.5 Software |
TB_20040426 |
| Map a Common Drive for all Network Client Workstations |
TB_102402 |
| Network Client - Retrieving Video Time Frame Errors |
TB_031503 |
| Network Client 2.0 Frequently Asked Questions |
TB_080701 |
| Network Client 3.0 and Database Repair |
TB_021103 |
| Network Client 3.0.15 Update |
TB_011403 |
| Network Client 3.1: Live Video is Sluggish, Technical Bulletin |
TB-00006-00-040608 |
| Network Client v2.3, No Dome Control |
TB_041002 |
| Network Client/Intellex 2.2.16 Known Limitations Report |
TB_101601 |
| Network Client/Intellex Player Warning |
TB_011603 |
| Network Client/Video Viewer Database Merge |
TB_082001 |
| Promise WebPAM Utility Does Not Support Intellex RMS v3.1 and v3.2 to Service Pack 1 |
TB-00012-00-041511 |
| Recording from DV8000 or DV16000 to a VCR |
TB_070802 |
| Restoring the Correct Features When Re-Entering the License Key After a Recovery Has Been Performed |
TB_20030806 |
| Sharp Tabs on Front USB Connector for Intellex |
TB-00011-00-041110 |
| Sharp Tabs on Front USB Connector of Intellex DVMS (v3.2) |
TB-00011-01-041110 |
| Three Extended Storage Modules |
TB_012902 |
| Unable to Play Back or Search for Video in Intellex |
TB_040402 |
| Video and Flat Panel Monitors on Intellex Platforms |
TB_20040413 |
| Video Over CAT5e Cable |
011402 |
| VM16 & Intellex v3.1 Incompatibility |
TB_20040107 |
| Zoom Graphics after Rebooting |
TB_121301 |
| Matrix Switcher/Controller Systems & Accessories |
| AD1024 Video Loss Detection Programming |
TB_062102 |
| AD1024CPU Compatibility |
TB_012802 |
| AD2031 and AD2032 Limitations |
TB_042803 |
| AD2150, AD32, VM32 Video Matrix Switch and AD2083 Series Code Translators - Avoid Reprogramming Due to Power Loss |
TB_092601 |
| ADTTE via AD1981 Port Expander |
TB_112002 |
| Clearing Patterns with Keyboards or Touch Trackers |
TB_040902 |
| Matrix Switcher FRU's |
TB_112901 |
| MegaPower 168 (AD168) - S3 Creating and managing multiple site databases |
TB_000899 |
| MegaPower 168 (AD168) Universal Bay |
TB_022201-01 |
| MegaPower 168 (AD168) version 3.3 software |
TB_062702 |
| MegaPower 48 Termination Issues |
100801 |
| MP1000CC Keyboard Matrix Interface Firmware Upgrade |
TB_051703 |
| Pseudo Numbers |
TB_061501 |
| S3 Matrix Switcher Programming Software |
TB_021102 |
| S3 System Transfers |
TB_012401-01 |
| SensorTrac & MP48 Compatibility Issues |
TB_080901 |
| Tech Tips - MegaPower 168 (AD168) Universal Bay |
TB_042702 |
| Technical Tips: MegaPower 1024 (AD1024) Satellite Networking |
TB_083001 |
| Video Overlay for Excalibur |
TB_021802 |
| VM16 & Intellex v3.1 Incompatibility |
TB_20040107 |
| VM96 & AD9414 Text Overlay Issue |
TB_20031121 |
| Quads, Multiplexers & Accessories |
| Multiplexer Compatibility Chart |
TB_ 032503 |
| Multiplexer Compatibility Issue with Standard Density VCR's |
TB_032803 |
| Multiplexer Frequently Asked Questions |
TB_062101 |
| Multiplexer Power Supplies Update |
072501 |
| Synchronizing a VCR to a Multiplexer |
TB_082901 |
| Analog VCRs & Accessories |
| Multiplexer Compatibility Issue with Standard Density VCR's |
TB_ 032803 |
| Synchronizing a VCR to a Multiplexer |
TB_082901 |
| Monitors |
| AD9615V, 15 Flat Panel Display |
TB_100702 |
| VM96 & AD9414 Text Overlay Issue |
TB_20031121 |
| Miscellaneous Documents |
| DAT Tape Reliability |
RB_021402 |
| Integra Digital Video Recorder |
TB_021301-01 |
| SensorTrac & MP48 Compatibility Issues |
TB_080901 |
| Sensortrac VTU Brush Replacement Procedure |
TB_051403 |
| Video Over CAT5e Cable |
011402 |
| Video Server Password Security |
TB_012103 |
SECURITRON TECHNICAL TIPS
| Magnalocks
Question: There is no magnetic attraction between magnet and strike plate.
Answer: First, be sure the lock is being powered by a DC source and that polarity is correct (RED to positive DC BLACK to negative DC). If the Magnalock is wired in reverse polarity, it won't be damaged, but it will not operate.
Second, if the unit continues to appear dead, it must be electrically checked with an Ammeter. It must be powered with the correct input voltage and checked to see if it draws the specified current. If the unit meters correctly, then the magnet body is operating properly and the problem must lie in the mounting of the strike.
Question: The lock is not holding properly (I can pull or tug it open ).
Answer: First, check the strike and magnet face to see if something is interfering with a flat fit.
Second, the strike must be allowed to float around the rubber washer stack which must be on the strike center mounting screw. The magnet then pulls it into flat alignment. If the strike is mounted too rigidly, proper alignment can't occur and the lock won't hold. To correct the problem, try loosening the strike mounting screw to see if the lock then holds properly.
Third, if you are operating the lock on AC instead of DC or on half wave rectified DC (transformer + single diode) the lock won't hold. Half wave rectified DC is unacceptable; you must, at a minimum, employ full wave rectified DC (transformer + bridge).
Question: The Senstat output is not reporting secure.
Answer: First, make sure that it is not reporting secure because a small obstruction or too stiffly mounted strike is causing the Magnalock not to hold properly. This problem can be corrected by cleaning the surfaces of the magnet and strike or establishing proper play in the strike mounting.
Second, verify function of the Senstat feature as follows:
Note that the core is seperated into 3 sections from left to right. The Senstat output is created by the strike establishing electrical contact between the leftmost and rightmost core segments.
With the lock powered, use a conductor to connect the two outside segments. If the Senstat reports secure, then the strike plate is not making proper contact with the lock face. If using a conductor doesn't cause the lock to report secure, check to see if there is a broken Senstat wire. If not the lock must be returned to the factory for replacement.
Question: The lock does not release.
Answer: When power is removed the Magnalock must release. If internal circuitry were to fail completely, the lock would only exhibit "stickiness" at a rough level of 5 pounds.
First, make sure that power is being removed from the Magnalock by the control device using a meter. If voltage is not dropping to zero check the control switches and wiring.
Second, check the face of the Magnalock and the strike plate for foreign material. Any material found should be removed using a piece of cloth and a non abrasive cleaner.
Question: The lock rusts.
Answer: Both the Magnalock core and strike plate are plated and sealed following a military specification. Because of this plating and the sealed nature of the magnet, the Magnalock is weatherproof and may be used outdoors. If rusting appears, the most common cause is that improper cleaning (with steel wool for instance) has occurred and this has stripped off the relatively soft plating. Once the plating has been removed, it cannot be restored in the field, so the lock will have to be periodically cleaned and coated with oil or other rust inhibitor. A rusty Magnalock will still function but at reduced holding force. If the product is installed in a heavily corrosive atmosphere, such as near the ocean, it will eventually rust even with non abrasive cleaning. The only answer then becomes continued periodic removal of the rust.
Question: Apparent electronic noise is interfering with the access control system.
Answer: Electric locks return voltage spikes on their power wires and also emit microwave radiation when switched. Note that Magnalocks include internal electronics which suppress both inductive kickback and radiation.
First, check the access control equipment it may be faulty or have been installed improperly.
Second, a problem can arise with the Magnalock. If the Senstat version is being used, the strike plate (which passes current) must be isolated from a metal door and frame. Securitron supplies insulating hardware to accomplish this but the hardware might not have been used or the strike may be scraping against the header for instance. Check for full isolation between the strike and the door frame (when the door is secure) with an Ohmmeter. The presence of lock voltage potential in the door frame can interfere with the ground reference of access control system data communication and therefore cause a problem.
|
| Touch Sense Bars
Question: The door does not release when the bar is touched.
Answer: First, press the back up release on the back of the bar if the door does not release the there is a fault in the systems general wiring. Check the system wiring.
Second, if the door does release when you press the back up release button check the sensitivity adjustment potentiometer on the back of the board turning the POT clockwise will increase the sensitivity and the bar may begin to function.
Third, if the door does release when you press the back up release button and you have tried adjusting the sensitivity then you need to check the voltage for the bar at the six pin connector that connects the cable to the board. Checking between red and black with a meter you should see system voltage.
Fourth, if the back up button works, you have tried adjusting the sensitivity and you have good voltage at the six pin connector check the antenna wire and make sure it is connected to the bar via the Phillips head mounting screw also check to make sure that the screw is not stripped. Meter between the face of the bar and the point were the antenna wire solders to the board you should see near zero resistance.
If everything checks out contact the factory.
Question: The door is always unlocked.
Answer: First, check for voltage at the lock if voltage is present and the door is not locked then the lock is the problem.
Second, if you do not have voltage at the lock check the sensitivity adjustment potentiometer on the back of the board turning the POT counter-clockwise will decrease the sensitivity and the bar may begin to function.
Third, if adjusting the sensitivity does not work try removing the red wire of the harness from positive DC if the door does not lock check for voltage between the white and black wire of the harness if you have no voltage then an upstream switch is more likely the problem.
Fourth, check the surrounding area for anything that might generate an RF field such as neon signs or loss prevention gates disconnect the device and see if the bar begins working properly, if it does then the addition of a 22,000 micro Henry inductor in-line between the board and the bar should solve the problem. If this does not work and everything else checks out contact the factory.
Question: I can't adjust the POT into a range were the bar works.
Answer: This is almost always due to use of a switching power supply. Try running the bar off of a clean DC source such as a battery (minimum 12VDC ) if the bar begins working you can try to clean up the supply by adding 2ea. 0.01 micro Farad capacitors to the supply one between positive and earth ground and one between negative and earth ground. If this does not work contact the factory.
|
| SAM
Question: There is no magnetic attraction between magnet and strike plate.
Answer: First, be sure the lock is being powered by a DC source and that polarity is correct (RED to positive DC BLACK to negative DC). If the Magnalock is wired in reverse polarity, it won't be damaged, but it will not operate.
Second, if the unit continues to appear dead, it must be electrically checked with an Ammeter. It must be powered with the correct input voltage and checked to see if it draws the specified current. If the unit meters correctly, then the magnet body is operating properly and the problem must lie in the mounting of the strike.
Question: The lock does not engage even though magnetic attraction is present.
Answer: The SAM operates by pulling the strike plate against the magnet face when the door closes, seating the conical buttons on the strike into corresponding machined holes at either end of the magnet body. If the buttons do not seat, the lock will not hold. There are three potential causes that can produce a failure of the buttons to seat.
First, the mounting alignment between the strike and the magnet body can be off so that the buttons don't line up with the conical machined holes in the T brackets. A misalignment greater than 1/8 inch end to end or front to back will cause engagement failure. You can normally visually detect such an alignment problem. Watch the strike closely as you very slowly close the door. You should see it "try" to move against the magnet body but note that the buttons are acting as stand-offs because they are not lining up with the holes. In some cases, this problem can be corrected by adjusting the door but re-mounting the unit properly is often required.
The second possible cause is that the gap between the magnet body and strike plate has widened to the point that the magnet can no longer pull the strike plate in. This can happen, for example, when the lock is mounted at the top of the door and the door sags downwards which increases the gap. Note that the gap is supposed to be 1/10 inch or the point at which the tops of the buttons just graze the magnet surface. If the actual gap is significantly greater than this, you have found the problem. It can be corrected by either readjusting the hanging position of the door or readjusting the level of the strike (by turning the two strike mounting screws) so as to reduce the gap to the correct dimension.
The final possible cause is that the strike mounting hardware has somehow become frozen so that the strike has lost its movement ability towards and away from the magnet body. You can check this by trying the move the strike by hand with the door open. If it will not move, dismount it and clean and lubricate (or replace) the mounting hardware.
Question: The lock is not holding properly (I can pull or tug it open).
Answer: First, Check the strike and magnet face to see if something is interfering with a flat fit.
Second, the strike must be allowed to float around the rubber washer stack which must be on the strike center mounting screw. The magnet then pulls it into flat alignment if the strike is mounted to rigidly proper alignment can't occur and the lock won't hold. To correct the problem, try loosening the strike mounting screw to see if the lock then holds properly.
Third, if you are operating the lock on AC instead of DC or on half wave rectified DC (transformer + single diode) the lock won't hold. Half wave rectified DC is unacceptable; you must, at a minimum employ full wave rectified DC (transformer + bridge).
Question: The Senstat output is not reporting secure.
Answer: First, make sure that it is not reporting secure because a small obstruction or too stiffly mounted strike is causing the Magnalock not to hold properly. This problem can be corrected by cleaning the surfaces of the magnet and strike or establishing proper play in the strike mounting.
Second, you can verify function of the Senstat feature as follows. Note that the core is seperated into 3 sections from left to right. The Senstat output is created by the strike establishing electrical contact between the leftmost and rightmost core segments. With the lock powered, use a conductor to connect the two outside segments. If the Senstat reports secure then the strike plate is not making proper contact with the lock face. If using a conductor doesn't cause the lock to report secure, check to see if there is a broken Senstat wire. If not the lock must be returned to the factory for replacement.
Question: The lock does not release.
Answer: When power is removed the Magnalock must release. If internal circuitry were to fail completely, the lock would only exhibit "stickiness" at a rough level of 5 pounds.
First, make sure that power is being removed from the Magnalock by the control device using a meter. If voltage is not dropping to zero check your control switches and wiring.
Second, check the face of the Magnalock and the strike plate for foreign material. Any material found should be removed using a piece of cloth and a non abrasive cleaner.
Question: Apparent electronic noise is interfering with the access control system.
Answer: Electric locks return voltage spikes on their power wires and also emit microwave radiation when switched. Note that Magnalocks include internal electronics which suppress both inductive kickback and radiation.
First, check the access control equipment it may be faulty or have been installed improperly.
Second, a problem can arise with the Magnalock. If the Senstat version is being used, the strike plate (which passes current) must be isolated from a metal door and frame. Securitron supplies insulating hardware to accomplish this but the hardware might not have been used or the strike may be scraping against the header for instance. Check for full isolation between the strike and the door frame (when the door is secure) with an Ohmmeter. The presence of lock voltage potential in the door frame can interfere with the ground reference of access control system data communication and therefore cause a problem.
|
| BPS Series Power Supplies
Question: There is no DC output from the power supply.
Answer: First, look at the LED on the outside of the box if it is on then the supply is working and the problem is probably an open poly switch (fuse). To correct this on the 1AMP supply, disconnect the load for 15 seconds, correct any possible system shorts and then reconnect the load. On the BPS series supplies over 1AMP each output if fused and the output LED will be on if the output is working. If the LED is out disconnect the output using the associated slide switch correct the system short and then reconnect the output with slide switch. The LED should go on and the system should operate. If all of the LEDs are out use a meter to check between F1 and F2 on the power distribution board if you see system voltage here then your fire alarm has disconnected the system.
Second, if the LED on the outside of the box is out check the AC input, if there is no AC voltage present you have found your problem.
Third, if AC voltage is present check the AC input fuse.
If the AC input fuse is good and you have checked everything else call the factory.
UnLatch Series
Question: Unit will not operate when trigger wire is connected to +V.
Answer: On a new installation, make sure that DC power (12 or 24 volts depending on the model) is connected to the red and black wires with correct polarity. When this is confirmed note that the UnLatch will never operate unless the springlatch plunger is pushed in by the springlatch. You can be "fooled" by this feature if you're trying to test operate the UnLatch with the door open. To circumvent this, use a pencil or other similar object to lightly push in the springlatch plunger and then close the trigger wire to +V and you will see the UnLatch plungers move. On a service call for a unit with successful operating history, in addition to the checks mentioned above, check to see if the door and latch have gotten into a warped situation where there is heavy pre-loading on the door. The UnLatch motor may not be able to release the latch under this condition, but you should be able to hear it trying to release the latch. The UnLatch will automatically shut down its motor if it can't release the latch within 1.5 seconds. It will operate normally when it is re-triggered. You should be able to try operation by removing the pre-loading by pushing the door closed with enough force to counteract the pre-loading. Note that this situation is more likely if power supply capacity is less than the recommended 3 Amps at 12VDC 1.5 Amps at 24VDC. To correct this "warped door" situation, have the door serviced and possibly increase the capacity of the power supply.
If the unit still will not function, note that it does have an internal microprocessor that could have gotten into a crash condition. This can happen some times if the unit is under-powered and has consequently stalled (the motor is not receiving enough power to operate the latch). While the motor is in the process of stalling, voltage to the processor will sharply drop and this can crash the microprocessor. A crash can also occur as a random event but this is unusual. The recovery technique is to de-power the unit, and then re-power it with the red and orange wires already connected (both then connect to +V). This re-initializes the firmware. Naturally, once this operation has been performed, return the unit to standard wiring (orange only connects to +V to trigger the unit.)
Finally, the unit could have experienced motor failure or other internal electronic failure. Call the factory.
Question: Occasionally the unit will not operate.
Answer: Generally, this comes from too much door pre-loading possibly coupled with a low capacity power source. When the UnLatch can't generate enough torque to release the latch, it automatically shuts down but then operates the next time it is triggered.
Question: The latch does not re-secure when the door re-closes.
Answer: This is not a problem with the UnLatch but is rather a problem with the installation. The latch is simply not moving into position. Make sure the door closer is properly operating to re-close the door with reasonable force.
Question: The latch status sensing does not function.
Answer: The latch status output will change state when the springlatch plunger is pushed in. To check this, push the springlatch plunger lightly in with a pencil or similar object. Make sure the unit is powered when you make this check or the output contacts will not switch. If they still do not switch, call the factory.
|
| DK Series Keypads
DK-11
Question: Entering the code does not unlock the door.
Answer: Note if the red LED on the Keypad Plate goes on after the code is entered. If it does then the system is functioning normally and you need to check the lock and lock wiring. If the LED flashes once quickly the lock is drawing to much current or you power supply is under rated for the system. If the LED does not go on then the code is not being accepted and you need to re-program the system. If this fails call the factory.
DK-26 and DK-16
Question: This unit appears dead.
Answer: Check that power has been connected using a voltmeter on the CPU board to make sure that the correct voltage is present. If the voltage reads very low, the problem may be that a fail safe lock being controlled by the DK-26 is drawing too much current for the power supply. Remove the lock from the circuit. If this restores proper voltage and operation of the DK-26, you'll have to determine if the power supply is undersized or if there is a short circuit in the lock wiring which is pulling down the power supply. If the DK-26 is receiving specified voltage, briefly short terminal SRC to terminal REX. You should hear the relay click. This confirms that the CPU board is working but for some reason, it's not reading the keys. Make sure that the keypad cable is connected exactly as shown in instructions. Pay particular attention to the keypad white wire going into terminal WHT. If this wire is not connected, the keypad will appear to be dead. If the relay doesn't operate when SRC and REX are connected, the CPU board has either tripped one of its automatic fuses or has some major problem requiring replacement. The DK-26 employs three special type fuses called PolySwitches.
PolySwitches look like capacitors. When a PolySwitch goes into overload, it automatically adds a high resistance to the circuit which limits current flow to about 100 mA, protecting the circuit. Each PolySwitch protects against a particular problem and you need to know how to determine if the PolySwitch has tripped and how to correct the problem and reset the PolySwitch.
PolySwitch #1 comes into play when you are powering the unit from an AC source connected to the AC input terminals. It protects against an internal short on the board. If you are powering the board with DC voltage into the DC input terminals, ignore PolySwitch #1.
PolySwitch #2 protects against an internal DC short circuit on the CPU board.
PolySwitch #3 protects against a short circuit in the keypad which can be caused by skinned keypad wires or mis-wiring the keypad cable into the CPU board terminals. PolySwitch #3 will also trip if there are short circuit problems with the SRC, REX, UCD and HCD terminals.
To check the PolySwitches, apply the probes of a voltmeter to both PolySwitch leads with the board powered. If you are checking PolySwitch #1, set your voltmeter to AC. Set it to DC for PolySwitches #2 and #3. In the normal condition, the PolySwitch will be conducting current so you will read less than one volt. A tripped PolySwitch acts as a high impedance resistor so you will read several volts across the PolySwitch leads. If none of the three PolySwitches have tripped but the properly powered board will not operate its relay when SRC and REX are briefly shorted together, call the factory.
If you find a tripped PolySwitch, you have reset it. Overload current through the PolySwitch trips it so that it clamps the current down to roughly 100 mA. The PolySwitch will continue to clamp until all power is removed for about 5 seconds. It is not enough to correct the overload condition; you have to depower the board for 5 seconds and the PolySwitch will reset itself.
If PolySwitch #1 has tripped, visually inspect the four large diodes on the board to see if a loose wire has fallen on them to create a short circuit. If you do not find such a physical problem that can be easily corrected, the board should be replaced although you should be aware that it can be operated with no problems from a DC power supply connected into the DC input terminals.
If PolySwitch #2 has tripped, and you are using DC power, make sure your input polarity is correct. Reversing your input polarity will trip PolySwitch #2. Otherwise, look for any loose wires that could be creating a short circuit anywhere on the board. If you can't correct the fault that is tripping PolySwitch #2, the board must be replaced.
If PolySwitch #3 has tripped, the overload condition is in the keypad wiring or in terminals SRC, REX, UCD and HCD. Carefully make sure that all keypad wires are connected to the correct terminals. If they are, temporarily disconnect the keypad and attempt to reset PolySwitch #3 by de-powering the board for 5 seconds. Once the board has been re-powered, momentarily connect SRC to REX to see if the board will function (the lock control relay will operate). If the CPU board resumes function, reconnect the keypad. If PolySwitch #3 trips again, the keypad will need to be replaced. If the CPU board did not resume function, disconnect any wires on the SRC, REX, UCD and HCD terminals and attempt reset. If this does not restore function to the board, the board will need to be replaced.
Question: Keys do not operate but I hear a beep every five seconds.
Answer: This is a diagnostic feature which indicates that one of the keys is being read as down (always being pressed). In that condition, the CPU board will not be able to read any other keys. It can happen because of mechanical failure within the switch element, or keypad wires that are shorted to each other. The latter problem usually happens when insulation is scraped off some of the wires in the keypad cable as it's being pulled through the door frame. You may be able to restore operation by rapping on all the keys. If this works, however, it is likely only a temporary fix and you should be prepared to change the keypad. Next, check the wiring of the keypad cable into the board. If you don't see any problems, the keypad will need to be replaced but you can restore partial use, if you wish, while awaiting a replacement. Put the positive probe of a voltmeter on terminal WHT and successively apply the negative probe on terminals BLK, GRY, BRN, BGE, ORG, PNK, and VIO. "Good" terminals will read about 11 volts. Two terminals, however, will read about zero volts. Remove the wires from the two terminals which read zero volts. If you are wondering why a single down key does not create a single zero volt terminal read, you should understand that the keys are in a two of seven matrix so the one to one relationship doesn't hold. When you remove the two wires from the zero volt reading terminals, you will disable several keys. You will be able to determine which keys are working by pressing each key and seeing which ones are echoed by a beep and LED flash. You can then establish a temporary Hard code using only the active keys.
Question: The keypad does not beep and the LED does not flash when a key is pressed (no echo).
Answer: A key is failing to be read when it is pressed. This can happen because of mechanical failure within the switch element, or from a broken or mis-wired keypad wire. If, however, the problem is with a wire, more than one key will be "dead". If just one key is not being echoed, the problem is with the key itself. You can, of course, use the unit for all operations that don't require that particular key but you will want to replace the keypad for full operation.
Question: Unit won't accept programming.
Answer: If the problem occurs on initial installation, usually it's caused by misunderstanding the programming instructions. Read them again carefully. Be sure you're not waiting more than 5 seconds between hitting keys as if you are, the entry will be ignored. Finally note that if terminals SRC and UCD are connected, all User codes will be disabled. If terminals SRC and HCD are connected, the Hard code will be disabled.
Question: The door opens on a short code that wasn't programmed.
Answer: This can arise through an unnoticed programming error. Suppose you want to program 4-5-1-2. But when the unit is in program mode, you forget to put in the two digit memory slot prefix but just directly enter 4-5-1-2. The microprocessor will accept this sequence and interpret it as code 1-2 in memory slot 45. You test the code by reentering 4-5-1-2 and the door opens because the sequence includes the real code, 1-2. Later it will be noticed that the door is opening on 1-2 as this is such a simple sequence that it will be entered. When you have any evidence that unknown codes (particularly short ones) are in the unit, it is best to erase all User codes and reprogram.
|
| Digital Entry Systems
Question: We have an existing DK-26 entry system with the keypad on the exterior of the door. Can we add a second keypad to the interior of the door?
Answer: Yes, you can add a second keypad to operate the same door. It can be any of the following keypads. DK-26PBK (narrow black - indoor/outdoor), DK-26PSS (narrow stainless steel - indoor/outdoor) or DK-16P (single gang - indoor).
Question: I would like to mount a DK-11 outdoors. Does Securitron offer a weatherized version?
Answer: No, we do not offer a weatherized version of the DK-11, but we do offer the WCC single gang weather cover and the WBB weather back box for the DK-11. The WCC and WBB will offer protection for the DK-11 when used outdoors, however, it still should not be used where it would receive direct rainfall. A caution should be noted here. The temperature range of the DK-11 is only operable down to +32 degrees F. If you have temperatures that drop below that range then do not use the DK-11 outdoors. A second concern would be the actual security of the keypad. The DK-11 is meant for lower security applications. Certain attacks on the DK-11 could cause the portal to open. Overall the DK-26 is a better choice for outdoor applications.
Question: I have read that your DK-26 can have 59 different user codes in the standard configuration, and 119 different codes in the expanded version. How many codes do I get with the Wiegand Output version?
Answer: Wiegand Output version has no built-in code capacity. The Wiegand Output version is meant to attach to the Wiegard card reader input of most card access control manufacturer's reader panels. Actual code capacity would be determined by the software/hardware configuration of the access control system.
Question: The electrician on a new construction project has put a single gang electrical box at the location that we are supposed to mount the narrow DK-26 keypad. Is there any way that we can mount this keypad to this box without leaving an exposed opening along both sides of the keypad?
Answer: Yes, we offer the DK-CPSS cover plate for this very application. It is drilled to mount to single gang box and cover the opening while still providing a mounting plate for the DK-26 keypad. The DK-CPSS is available on in the stainless steel finish and is approximately 3" X 8" in size.
Question: I have an existing electric strike and transformer. Will that be enough to power the strike and keypad?
Answer: No, usually you will need to provide separate power for the keypad system. If the strike has a large enough in-rush current to max out the transformer, the keypad system will crash. An inexpensive plug-in D/C power supply would suffice, such as Securitron part # PSP-12 or PSP-24.
| Exit Control / Push Buttons |
Exit Delay Systems |
| Industrial Cabinet Locks |
Keyswitches |
| Latch / Bolt Monitors |
Lock Control Panels |
| Magnalocks |
Question: I have a door that has a closer and other apparatus at the top of the door. As a result there is not enough room to mount the Magnalock . Can I mount the lock on the jam rather than the header.
Answer: Yes, mounting the lock on the jam will not change the functionality of the Magnalock.
Question: I have an in-swing door. I don't want to mount the Magnalock on the unprotected side of the door. What do I need to mount it on the inside (in-swing side) of the door?
Answer: We offer a series of "Z" brackets for this requirement. Typically you can face mount (use the "F" suffix lock, for example: M62F) the Magnalock above the door on the header. On the door mount the "Z" bracket (such as the Z-62CL) and then mount the strike plate to the "Z" bracket.
Question: Are your Magnalocks available in any other finish?
Answer: No, the only finish on our Magnalocks is the standard satin stainless steel finish. However, we do offer a series of dress covers that meet most requirements. The dress cover will cover the entire assembly providing the desired finished appearance and as an added bonus it provides additional tamper resistance to the lock. Available finishes include BK-Black Anodized (example: DC-62BK), BP-Brass Polished (example: DC-62BP), CL-Clear Anodized (example: DC-62CL) and SP-Stainless Polished (example: DC-62SP.)
Question: I have a set of double doors. I want to lock both doors with the Magnalock product. Do I need two separate locks (one for each door)?
Answer: Possibly! Using two individual locks is certainly an option. Another option is to have two Magnalocks in a single housing such as the DM62. A third option with a double door (assuming that there is no center mullion) could be to use one magnet mounted in the middle of the jam with a split strike option. One split strike plate would mount to each door. An example would be the M62-SS which is a M62 Magnalock with a split strike. Be advised that you will have something less than half of the rated holding power of a given lock on each door leaf. For example the M62 has 1,200 lb. holding force, but with a split strike each door will have something slightly less than the expected 600 pound holding force due to the smaller strike surface area.
Question: I have a high security application. It is important that for us to confirm that the lock is actually locked. Just knowing that the door is closed is not sufficient. Do you have anyway for us to confirm a locked condition on the Magnalocks ?
Answer: Yes, by adding the Senstat (SC) option (example M62SC) to the Magnalock you will get a lock with an output that confirms the lock is secure. This feature confirms that the door is closed and locked.
Question: I am having difficulty figuring our which lock is best for my various applications. Is there a "rule of thumb" that I should use?
Answer: Every application will have different requirements, but in general the following guide should help.
| Door Type |
Suggested Magnalock |
| Typical "Storefront" aluminum over glass |
M32 series or M34 series |
| Sliding Door |
M34R (R-recessed option) |
| Wood or metal door requiring a concealed installation |
SAM series |
| Herculite Door (with top & bottom rail) |
SAM series |
| Bi-Swing Door |
SAM series |
| Interior office door or corridor door (low to medium security) |
M32 series or M34 series |
| Interior office door or corridor door (medium to high security) |
M62 series |
| Steel Door (such as warehouse exit) |
M62 series |
| Very High Security such as a door in a detention center |
M82 series |
| Super High Security susceptible to attack such as a detention holding area |
Dual M62 or Dual M82 in full length vertical housing |
| Swinging Gate (Man Gate) |
M62FG with M62Z bracket |
| Swinging Gate (Vehicle Gate) |
M62FG with Z-62 bracket or M82SCFG w/Z-82 bracket |
|
Maximum Security Switches
Motion Detector Exit Package
Power Sources
Question: I have used the Securitron power supplies on various access control projects. Do you offer anything for our CCTV installations?
Answer: Most CCTV installations require 24vac for camera power and Pan & Tilt power. For those requirements we offer the BACS-24-10. It supplies 10 amps of 24vac power. It includes a CCS-8A circuit board with eight individually switched outputs. Each of the eight outputs includes its own automatic circuit breaker. Additional outputs can be added with CCB-8A slave boards.
Question: I have a requirement that states that I must automatically unlock all my doors upon the activation of the fire alarm system. I plan to use a common power supply for my locks, but which Securitron power supply must I use?
Answer: Any of the Securitron BPS series power supplies can be interfaced with a fire alarm system. The fire alarm system must provide a relay output for connection to switch the BPS power supply. The fire alarm relay must be able to carry the entire load of the power supply, i.e. if you have a BPS-24-10 then your fire alarm relay must be able to handle 10 amps at 24 vdc.
Question: My customer is concerned that if the main electrical power is lost to the facility and the lock power supply goes to battery backup over the weekend it may create a condition where the locks unlock if main power is not returned before the batteries discharge. Is there anyway to set off an alarm should main power fail?
Answer: Yes, we manufacture the PSM - Power Supply Monitor for that very purpose. Available in either 12 or 24 volt versions it will work with any of our BPS power supplies of 2 amp or greater capacity. It also does three checks of the battery pack each day to make sure the batteries are fully charged.
Question: I am configuring my system. The various components when added together are going to draw approximately 830mA at 12 vdc. We need to have battery back up. Is the Securitron BPS-12-1 the correct power supply to use with this system?
Answer: No, we recommend that you allow 25% for a "Margin of Error" on any of our power supplies. This 25% allows for the current draw of the charging circuit as well as possible extra draw from long cable runs, etc. Therefore, 750mA is the largest load we would recommend for the BPS-12-1. The appropriate supply for your application is the BPS-12-3.
Question: We have configured our system. We intend to use a Securitron BPS series power supply. We now need to figure out the size of our battery back up. What is the best method to calculate this requirement?
Answer: In order to calculate your battery requirement you need to know two things. First, what is my total load or current draw, and second how long (maximum length of time) do I need to maintain the load on battery. Add up all of the current draws of the items in your system. For example you might have a system with (2) M62 Magnalocks drawing 125mA each, (2) TSB-3 Touch Sense Bars drawing 25mA each, (2) DK-26 Digital Keypads drawing 190mA each, and (1) DT-7 seven day timer drawing 160mA all at 24vdc. Your total current draw will be 840mA. You would, therefore, need the BPS-24-2 power supply. If you need to back up this supply for four hours then you could use the chart below. The closest rating above 840mA is the 1A line. Go over to the 4 hour back up time and you will see that you would need 8 AH of batteries to maintain this system for four hours. If you use 12vdc batteries then you will need (2) 12v/8 AH batteries wired in series for this 24vdc supply.
Question: Can I use a Touch Sense Bar on a Fire Door?
Answer: No, hardware requirements for a listed Fire Door would not allow the use of the Touch Sense Bar.
Question: Is it possible to use a Touch Sense Bar as part of my Exit Delay System?
Answer: Yes, the Touch Sense Bar is an excellent choice for initiating an Exit Delay System on non-fire rated doors.
Question: I know that Securitron offers the Touch Sense Bar in standard sizes of 36", 42" and 48" lengths. I am working with a door that is an odd size. Can I use one of the standard length bars or do I have to place a custom order?
Answer: As long as your door does not exceed 48" you can order the standard bar that is longer than you need and cut it down in the field to the exact dimension required for your installation.
Question: We need a different color Touch Sense Bar, other than black or aluminum. Do you offer any other finish?
Answer: No, but you can easily and inexpensively have them powder coated to almost any finish required.
Question: Do I have to use a Securitron power supply with the touch sense technology?
Answer: No, not necessarily. They do require a linear power source. They will not operate properly on a switching power source. There are several power supplies used in our industry that are switchers. (contact tech support at Securitron if you're not sure ) All of Securitron's power supplies are linear.
|
| UnLatch Series Door Strikes
Question: I would like to use the UnLatch and Mortise UnLatch on an upcoming project. What do I need to do to prepare the jam to accept these strikes?
Answer: Probably nothing! The advantage of the UnLatch series is that it replaces the standard ANSI 4-7/8" strike plate without any cutting or modification. If you already have the door prepared for a 4-7/8" strike plate you are ready to go. Just verify that there is sufficient space in the jam to accept the body of the lock. The UnLatch requires 3-3/8" Long, 1-3/8" Wide, 2" Deep while the Mortise UnLatch requires 3-3/8" Long, 1-7/8" Wide, 2" Deep.
Question: I don't work with electric locks very often. How do I determine whether I need an UnLatch or a Mortise UnLatch?
Answer: The UnLatch works with a cylindrical type spring latch or dead latch. The Mortise UnLatch works with a mortise lock. You can use the following illustrations to identify you lock:
Typical Cylindrical Lock (Use the UnLatch with this type of lock)
Typical Mortise Lock (Use the Mortise UnLatch with this type of lock)
Question: We are considering using the UnLatch lock for an upcoming project with an access control system. One of the doors is going to be unlocked during business hours. Is the UnLatch rated for continuous operation?
Answer: One of the great benefits of the UnLatch is its motor driven mechanism. Unlike solenoid operated strikes that can overheat when the lock is held unlocked for extended periods of time, the UnLatch merely repositions the plungers and then waits for the re-lock command. As a result there is no overheating, as there is no solenoid being held.
Question: I need to know the minimum wiring requirement for the UnLatch.
Answer: There are six wires on the UnLatch. Two are there for power, one to trigger the lock and three to provide an output to show lock status. Therefore, the minimum number of wires required to operate the UnLatch is three. Two for power and one for the trigger.
Question: How far can I mount my power supply from the UnLatch lock?
Answer: That depends up on two factors. First what is the operating voltage, 12vdc or 24vdc. Second is what is the gauge of wire. The following chart will show you the allowable distance based upon operating voltage and wire size.
|
HIRSCH TECHNICAL TIPS
HID TECHNICAL TIPS
Installation instructions, wiring diagrams, manuals and guides for HID Proximity, MIFARE, iCLASS and Dorado by HID readers are available here for download as Adobe Acrobat PDF and MS Word documents. For more detailed information for specific applications, see HID's Application Notes.
| Proximity Products
iCLASS Products
|
MIFARE Products
HID Magnetic Stripe Products
VertX CS Products
|
HID APPLICATION NOTES
FORMANT GUIDELINES
26 Bit Format: H10301
General: The 26-bit format is the industry standard format, and is an open format. The sale of this format is not limited to any one company. The range of card numbers available in this format is limited and therefore there is a potential for card numbers to be duplicated. It is important to understand that HID does not insure that card numbers will not be duplicated. HID does not control or restrict the ordering of cards encoded with the standard 26 bit format. Convenience in ordering cards and universal access control panel acceptance are the primary benefits in using the standard 26 bit card format.
Description: The 26-bit format consists of 255 possible facility codes. Within each facility code there is a total of 65,535 unique card numbers.
Sales Policy: This format can be sold to any customer.
HID Proprietary 37 Bit Format: H10302
General: In an effort to provide an open format to the industry, while at the same time provide assurance that the numbers are unique and will not be duplicated, the 37 bit format was developed. Under this format, HID controls the issuing of card numbers and does not duplicate the numbers.
Description: The 37-bit format can be used to program a wide range of unique card numbers. Although it is available to all customers, not all access control systems can handle such a large data length format. In addition, many systems are unable to handle a format that does not have a facility code.
Sales Policy: Just like the 26 bit format, the 37 bit format can be sold to any customer. Although it is available to all customers, HID controls the numbers to be generated for each order. Confirm that the system that the cards are to be utilized on is capable of using a 37-bit number with no facility code.
HID Proprietary 37 Bit Format with Facility Code: H10304
General: The 37-bit format with facility code differs from the 37-bit format only in that it also contains a facility code. Just like the 37 bit without facility code, this format provides the customer with an open format in which card numbers will not be duplicated, because HID tracks the manufacture of cards to prevent duplication.
Description: This 37-bit format has 65,535 facility codes available and over 500,000 card numbers within each facility code. Just like the 37-bit format without facility code, many systems are not capable of handling a format as large as 37 bits. In addition, many systems are not capable of handling a facility code as large as 65,535.
Sales Policy: The 37 bit format with facility code is ideal for dealers who would like to have their own format. This allows them to have the security of no duplication of cards, while at the same time they are not dependent on any system supplier for a format. This format is reserved for those customers with a requirement for a large population of cards.
Corporate 1000 Format (see the Corporate 1000 page for more details)
General: The Corporate 1000 format is a 35 bit format designed to provide large end users with their own proprietary format. This provides them with an assurance that their cards will not be duplicated, because HID reserves an exclusive Corporate 1000 format for each OEM. This format also provides the end user the freedom to work with any system and with any dealer of their choice. Some access systems are not capable of handling a 35-bit format, but as a service to the customer, many OEM's will make enhancements to their control systems to allow the use of an HID Corporate 1000 format. The end user is offered the security and flexibility of selecting and authorizing the security dealer of their choice and controlling the issuance of cards for their organization.
Description: The Corporate 1000 format is a 35 bit format with a unique Company ID Code and over 1,000,000 card numbers available for use.
Sales Policy: The Corporate 1000 format offers the end user a large quantity of available card numbers and is typically reserved for those customers with the need or potential to badge a large number of card holders. The Corporate 1000 format is also available to large organizations that are geographically diverse and have a requirement to unify the structure of their access control system around an exclusive access control card format under their control.
HID LONG FORMAT CARD PROGRAMMING
HID Long Format Card Programming allows up to 84 bits of user data to be encoded on a card and transmitted by a reader to the OEM access control panel or other host controller.
Applications
Long Format allows HID compatibility with longer Wiegand formats sold in Europe, allows emulation of existing Clock and Data (magstripe) formats and allows new OEM formats to be created with longer bitstreams for more security.
Although identified by the reader hardware interface typically used, any available hardware interface (Wiegand, Clock and Data or Serial) can be used with any data structure type.
Requirements for Use
Cards - Standard cards may be ordered so long as the correct format number is specified when ordering. Long format card programming is available with all HID field programmable passive transponders except for the ProxPass, a long range active transponder.
Readers - Special part numbering is not required for readers, but they must have current firmware. Please be sure to specify Long Format when ordering and check with HID Technical Support if you have any questions.
HID readers do not have to be specially configured to read and transmit long
26 Bit Format: H10301
General: The 26-bit format is the industry standard format, and is an open format. The sale of this format is not limited to any one company. The range of card numbers available in this format is limited and therefore there is a potential for card numbers to be duplicated. It is important to understand that HID does not insure that card numbers will not be duplicated. HID does not control or restrict the ordering of cards encoded with the standard 26 bit format. Convenience in ordering cards and universal access control panel acceptance are the primary benefits in using the standard 26 bit card format.
Description: The 26-bit format consists of 255 possible facility codes. Within each facility code th |